Level 4 tier 1 electrical submersible pumping systems artificial lift 907140 rev. Disadvantages of a 12 pulse rectifier are costdue to the special. Dcdc power converters are employed in a variety of applications, including power supplies for personal computers, office equipment, spacecraft power systems, laptop computers, and telecommunications equipment, as well as dc motor drives. In this connection, problems associated with current sharing are avoided and an interphase reactor is not. Using the same converter configuration, it is possible to combine two bridges of the six pulse to obtain a twelve or more pulses converter. A 24pulse acdc converter for improving power quality. A 24pulse acdc converter employing a pulse doubling. It is observed that input current total harmonic distortion thd of less than 8% is possible with the proposed topology of acdc converter at varying loads. So, a 24pulse acdc converter is designed and simulated to feed isolated industrial loads.
The voltage reduction transformer and 24 pulse phase shifter has a primary winding designed to be connected to power supplies with voltages of 34. The 36 pulse rectifier offers a higher quality input current line current while that of the 24 pulse. This requires an 18 pulse bridge and correspondingly expensive input transformer at a minimum, and generally 24 pulse or higher for large drive systems. It involves pulse multiplication in a 12 pulse acdc converter. Multi pulse converter transformer series and parallel. A lowripple pulse skip mode reduces the noload supply current to 152. A 24pulse acdc converter for improving power quality using.
The wt signal is an angle varying between 0 and 2pi radians, synchronized on zero crossings of the fundamental positivesequence of phase a of the primary voltage of the converter transformer. The size of the twelve pulse rectifier with this arrangement is reduced to 18% of the conventional 12 pulse rectifier and reducing ripple content at the output side. The results confirm the viability and applicability of the proposed converter in hvdc transmission systems. The major cause of this deviation is because of the harmonics introduced by the switching of solid state devices. Chapter 2 controlled power operation of 12 pulse converter. An alternative proposal for hvdc transmission systems using. Bear in mind that the transformer is designed only for one type of power source voltage. In this paper 12 pulse converter with differential delta connection arrangement to enhance the utility power quality of high current dc power supplies have been introduced. With the 6 pulse rectifier described above, the 5 th and 7 th order harmonics are significant, and filtering is often needed. Set the order of pages by moving and then create pdf. Results suggest that the total harmonic distortion, thd, produced by an ideal 6 pulse rectifier is higher than the ieee limit and therefore higher order pulse rectifier must be used to control the thd. An active interphase transformer for 12pulse rectifier.
Converts a pulse signal to an analog signal and outputs the result. However, in addition to using the same number of 6 pulse acdc converters, a reconfiguration and monitoring. Keywords 24 pulse, acdc converter, power quality, tyristor bridge, pulse multiplication, polygon autotransformer. Lci drives have either 6 pulse or 12 pulse source converters. A laboratory prototype was designed and executed based on transformers with extended delta primary windings to validate the proposed 24 pulse converter in terms of harmonic mitigation and improved power quality. Ac line current waveform total harmonic distortion total harmonic distortion of ac line current of the 18 pulse converter system is very high i. Analysis of 12 and 24pulse diode rectifiers operating in aircraft. Then, the best form of a 12 pulse converter will be used to build a 24 pulse converter. What is a pulse rectifier and what kinds are there. Pdf simulation and hardware of 24 pulse controlled.
Pdf in this paper,a 24pulse rectifier has been designed for high voltage applications. In this paper multipulse converter with 6, 12, 18, 24 and 36 pulse. Practical experience with differential protection for. A transformer with one primary and two secondary windings creates a 30 degree phase shift between the two current waveforms, which eliminates the 5 th and 7 th harmonics and reduces current thd to between 10 and 15 percent. The existing acdc converter using a transformer which does not meet the standard requirement at varying loads and also causes the low power factor which is responsible for a series of problems caused in electrical system. In this converter, the number of pulses is twice that of phases, that is p 2m.
The input to a dcdc converter is an unregulated dc voltage vg. Linearizes a signal that does not have linear output characteristics and outputs the result. Modeling of a 18 pulse converter for improving quality in. Some loads require high currents, others high volta. Electrical schematic below showing 12 pulse vfd with two. The rating of the magnetic part of this system is reduced by 30% when compared to 24 pulse system. Pdf simulation and hardware of 24 pulse controlled converter. Design of the proposed 24 pulse acdc converter this section presents the design technique for achieving 12 pulse rectification in the proposed acdc converter. Chapter 2 controlled power operation of 12pulse converter. And also the harmonics comparison of 24 pulse converter over the low pulse converter.
Indeed, the rle load shown in this figure may represent the electrical. Multi pulse converters are converters providing more than six pulses of dc voltage per cycle or the converter is having more steps in ac input current than that of six pulse rectifier supply current. This article deals with autotransformer based multipulse acdc converters feeding vector controlled induction motor drives vcimds for improving power. For example, a dual channel system with two 12 pulse source converters can be connected for 24 pulse harmonic currents. Select your pdf files you want to merge or drop the files into the file box. This leads to taking the hexagon as the first choice in minimizing the harmonics. The 38 pulse converter was adopted for keeping us navy requirement of input thd below 3%, and the 40 pulse one was designed for vcimds which has thd variation of 2. This 24 pulse rectifier has been designed for high voltage current application by connecting them in seriesparallel respectively. Us5068774a 24pulse hexagontype acdc static converter. A 24pulse acdc converter for improving power quality using fork.
Converts an analog signal to a pulse signal and outputs the result. In a 24 pulse rectifier 3phase supply is given two delta to star and delta transformer connected to two 3 phase bridges converting 3 phase ac to dc. Use of higher pulse converters, such as 24 pulse rectifiers, can eliminate lower harmonic values, but at the expense of creating higher harmonic values. The 24 pulse stepdown phaseshift transformer has a primary winding designed for connection to power sources with voltages of 34. These rectifiers are fed through a transformer with three or four secondary transformers respectively. After that implementation of multi pulse controlled converter of 24 pulse will be design using suitable technique.
Click on the pages you want to add to the new file. One way to reduce thd in an ac drive is to use a 12, 18, or even 24 pulse rectifier. A twelve pulse system can also be constructed from two six pulse rectifiers connected in series. The figure below shows a six pulse bridge controlled converter connected to a threephase source. Variable frequency drives a comparison of vsi versus lci. This converter draws almost sinusoidal currents from the ac. The proposed 24pulse acdc converter is found capable of suppressing up to the 21st harmonics in the.
Simulation and implementation of multipulse converter. Designing and harmonic analysis of shunt hybrid filter with. A 12pulse rectifier is formed by combing two 6pulse rectifiers fed from two 3 phase systems dislodged by 30 the 24pulse rectifier. Note that low power ttl logic will not drive this unit. Set the order of files and create pdf or switch to expert mode. Thd of 18 pulse converter to reduce these total harmonic distortion and. Nov 09, 2014 this requires an 18 pulse bridge and correspondingly expensive input transformer at a minimum, and generally 24 pulse or higher for large drive systems. International journal of emerging technology and advanced. Differential protection solution for a 24 pulse converter transformer differential protection installation on the 24 pulse drive for the oil industry is given in figure 4. Electrical schematic below showing 12pulse vfd with two. It is one of the most popular converter circuits and is widely used in the speed control of separately excited dc machines. Jul 10, 2009 the proposed converter consists of a newly designed hexagonconnected autotransformer with reduced magnetics rating and having simplicity in design and manufacturing. Hink mte corporation w147 n 9525 held drive menomonee falls, wi 53051 telephone 2622538200. The waveform of individual 6 pulse converter are demonstrated in figure separately.
In this configuration, two six pulse rectifiers, each generating one half of the dc link voltage, are series connected. Issues of power quality are mainly concerned with the deviation of the current or voltage from its ideal waveform. Simulation of 3 phase, 24 pulse gto converter for flow. A 24 pulse acdc converter for improving power quality using fork connected transformer abstract. The conventional rectifiers are created using diodes and thyristors. The device survives loaddump pulses up to 45 v per iso 7637. Through the analyzes carried out, it is concluded that 12 and. Note that in this installation two separate transformers i. Abb medium voltage drives product overview 3 general purpose medium voltage drives special purpose medium voltage drives type acs acs 2000 acs 5000 acs 5000 acs 6000 megadrivelci output voltage 2. Visintini elettra synchrotron light laboratory, trieste, italy abstract in particle accelerators, rectifiers are u sed to convert the ac voltage into dc or lowfrequency ac to supply loads like magnets or klystrons. High power conversion technology for high voltage dc.
A new harmonic mitigator based on 24pulse acdc conversion is proposed to feed voltage source inverter supplying squirrelcage induction motor drive. The 100% free pdf creator and pdf convertor supplied by works with all windows programs and has a lot of features you wouldnt expect from free software. Nov 12, 2014 24 pulse rectifier consists of 24 diode, 3 phase supply. The autotransformerbased structure leads to a circuit of lower cost, weight, volume and space when compared with the conventional 6 pulse acdc converter. The proposed system is robust and simple with 400hz supply frequency. Abstracta new converter topology for a threephase multi pulse rectifier circuit is described. Design of the proposed 24pulse acdc converter this section presents the design technique for achieving 12pulse rectification in the proposed acdc converter. The pa1 offers a unique way of adding a single channel of analog output to any plc. Pdf multipulse converters are developed for ac dc conversion with reduced harmonic currents and reactive power burden, low emi, rfi at. In this project the simulations of multi pulse controlled converters is included using different phase shifting transformer design such as delta, wye, zigzag, star, polygon, etc. Multipulse converters 1 defined as diodethyristor converters where the pulse number is 6 remember, the ones we have looked at so far have been 6 pulse generally the pulse number is a multiple of 6 assuming 3phase system, so 12, 18, 24 pulse circuits etc are possible a 12 pulse converter, for example, consists of two 6 pulse converters fed from a 6phase supply and connected in series. As an alternate, active front ends consisting of what is for all intents and purposes a transistor based inverter section can also be used. Two twelve pulse converters phase shifted by 15 degrees from each other, can provide a twenty four, obviously with much lower harmonics on ac and dc side. The proposed configuration consists of an isolation transformer.
Afterwards, 38 pulse and a 40 pulse based autotransformer converters are reported in 24 and 25, respectively. Ac to dc converter, rectifier, thd, thyristor, atp i. A 24 pulse converter system is obtained, and it is a matter of choice in the light of the embodiments previously described, to select variations therefrom. The two independent channels require 7ma into 382 ohms to provide a 7ma output into the 3k, 24 volt typical plc logic inputs. Harmonic mitigation of 12 pulse drives with unbalanced input line voltages karl m. A 12 pulse rectifier uses two 6 pulse rectifiers in parallel 12 diodes to feed a common dc bus. Two converters will, then, be combined in series or in parallel, so as to obtain a 24 pulse system, thereby cancelling the dominant 11th and th harmonics.
The proposed system can be designed by linking to individual 6 pulse channels in series to form a 12 pulse acdc converter system instead of auto. T1 and t2 are used to build the converter transformer. A simplified analysis of the 24pulse rectifier was also performed using two input filters. Another tconnected autotransformerbased 24 pulse acdc converter has also been presented in 18, however, the thd of the supply current with this topology is reported to vary from 2.
If multiple converters are used in a system, the transformers for the system can be designed with secondary phase shifts that result in low harmonics on the ac system. Generate pulses for twelvepulse and sixpulse thyristor. Output voltage 05vdc or 010vdc can be adjusted up or down in 1% increments by. Index terms bridge converter, three phase multipulse rectifier circuit, low harmonic. The pulse generator thyristor block is controlled by the alpha angle reference signal and by the synchronization signal wt. They may be driven by standard or h series ttl logic, or with an open collector npn transistor. Thd of 18 pulse converter to reduce these total harmonic distortion and maintain quality in ac line current we are using 3. One advantage is that this 24 pulse converter can only operate in a 12 and 18 pulse system in degraded mode and therefore has proven to be more advantageous and attractive in terms of reliability than the systems shown in fig.
172 1168 709 714 38 926 1597 1569 1371 450 715 1267 917 755 479 1289 999 190 1384 519 1077 872 521 998 823 1493 356 1106 987 413 883 1425 137 950 441 264